--> Comark | N2014 Temperature Logger (Accessories to add: N2000ADP/K 3 Probe Adapter Cable) | Data Loggers | $139.00 | From Tech Instrumentation
Menu
Cart 0

N2014 Temperature Logger (Accessories to add: N2000ADP/K 3 Probe Adapter Cable)

No reviews
  • $139.00


N2014 Temperature Data Logger
Diligence EV temperature and humidity data loggers feature compact, durable, lightweight design for use in many applications including the food, pharmaceutical and chemical industries and the monitoring of medicines and other sensitive materials in transit or storage. The loggers are also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems, and countless other applications.

Requires 3 Probe Thermocouple Adapter Cable (N2000ADP/K) for use with multiple probes.
Thermocouple probes can be used in a wide variety of applications and have a variety of options allowing you to choose a temperature probe that works best for you!
** Click Here to see all Compatible Thermocouple Probes (requires N2000ADP-K Option) **

REQUIRED OPTIONS:  (See options above)

  • N2000ADP/K if using with standard Thermocouple probes or if using with multiple probes
  • N2000CRU - One required per computer you are using with the N2014 regardless of the number of loggers being used.
  • Probe(s)

Features:
Four total channels with up to 3 external thermocouple probes
Connect up to 3 external type K Thermocouple probes via the N2000ADP/K adapter cable (included)
Audible & visual alarm indications
LCD display for temperature readings and alarm indication
Wide measurement range from -200 °C to +1372 °C (type K)
Tough, molded cases, dust and waterproof to IP67 standards
Large memory capacity of up to 16000 readings
Ability to log over multiple periods
Compatibility with the versatile and proven Evolution Windows software
Single, multi-function button
LED indicators to show active logging and alarm conditions, plus audible alarm warning
Long battery life of up to 5 years
Two year warranty
Requires N2000 Interface Cradle with EVSW Software (See option 1. One required per PC regardless of the number of N2014 loggers you purchase.)

 

Specifications:

Sensor Type Thermocouple Type T
Thermocouple type K
Thermistor
Measurement Range
Type K -200 °C to +1372 °C/-328 °F to +2502 °F
Type T -200 °C to +400 °C/-328 °F to +752 °F
Thermistor -40 °C to +70 °C/-40 °F to +158 °F
Scales °C and °F
Resolution (Thermocouple) 0.2 °C up to and including +300 °C
0.5 °C above +300 °C
Accuracy at +20 °C, ambient ±0.5 °C +0.3% of reading
Accuracy at -20 °C to +40 °C, ambient ±0.5 °C +0.5% of reading
Accuracy at -40 °C to +70 °C, ambient ±1.0 °C +1.0% of reading
Accuracy at -20 °C to +40 °C ±0.3 °C Thermistor
Accuracy at -40 °C to +70 °C ±0.5 °C Thermistor
Memory 32K
1 channel 16000 samples
2 channels 8000 samples
3 channels 5300 samples
4 channels 4000 samples
Communications Via infra red interface
Download Time 3 minutes for 10,000 readings (typical)
Logging Frequency Programmable between 1 second and 99 hours
Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
Ambient Storage -40 °C to +70 °C/-40 °F to +158 °F
Logging Start Programmable date and time or manual start from instrument multi-function button
Software Windows based software for N2014 (Download Here)
Battery Type 1 x AA size 3.6V replaceable lithium battery
Battery Life Up to 5 years
Case Material ABS
Environmental Protection IP67 BS EN 60529 IEC 529
LED Indication
Red Alarm
Green Logger Active
Dimensions
Length 88mm/3.5ins (including fixing lug)
Width 80mm/3.1ins
Depth 35mm/1.4ins